Project Description

ICJ02

Sproull® ICJ Chemical Centrifugal Pump is single-stage end-suction (axial suction) cantilever typecentrifugal pump, which is used to transport corrosive liquid with viscosity similar to water and without solid particles. The marked and rated performances and dimensions adopt IS02858 international standard,the manufacturing technical conditions are in accordance with ISO5199 and the structural design is in accordance with API610.
This series pump is a new improvement of h series pump. It adopts the mechanical seal and various technical measures to reduce the shaft diameter, so as to improve the whole pump performance.

Working Condition:

Capacity: 2-650 m³/h
Head: 3.5-150 m
Working pressure:<1.6Mpa
Working Temperature:-50℃- +200℃
Materials:316、316L、HastelloyC,B、C4、20*alloy、8#alloy CW-2 etc.

Design features:

•Compare with the IH pump,Large cone-angle cavity of axle seal box. The machine seal is placed in a spacious cavity.
•The Container Type double-faced mechanical seal effectively realizes the forced circulation cooling in the mechanical seal.
•The enlarged shaft diameter reduces the deflection of the rotor and makes the operation stable.
•Simple structure, easy maintenance.

Sproull® ICJ Chemical Centrifugal Pump is applied to transport various corrosive media or media in which pollution is forbidden similar to water in such industries as chemical industry, petroleum, metallurgy, electric power, papermaking, food, pharmacy and synthetic fiber etc.

Sproull ICJ Chemical Centrifugal Pump PA

Structure Drawing of Type Sproull® ICJ Pump

ICJ06
1 O-ring 5 Wearing ring 9 Bearing support 13 Suspension bracket
2 Wear-resistant rubber lining 6 Casing cover 10 Shaft cup 14 Water cooling jacket cover
3 Impeller 7 Cartridge mechanical seal 11 Rear bearing cap 15 Front bearing cap
4 Volute casing 8 Shaft 12 Dust cover 16 Baffle ring

Sproull® ICJ Preformance Curve(Demonstration)

ICJ07
lllustrations of Model Type
ICJ200-150-400
ICJ GB standard single-stage single suction chemical industry pump
200  refer to pump suction diameter(mm)
150 refer to pump dischange diameter(mm)
400  refer to impeller nominal diameter(mm)

Sproull® ICJ Preformance parameter list

Type Speed
n(r/min)
Capacity
Q(m³/h)
Head
H(m)
Eff
η(%)
Shaft power
pa(kw)
Motor power
(kw)
NPSHr
(m)
50-32-250 1450 6.3 20 27 1.27 2.2 1.2
50-32-250 2900 12.5 80 33 8.25 15 2.0
65-40-250 1450 12.5 20 39 1.75 4 1.2
65-40-250 2900 23.3 69 46 9.52 15 2.5
80-50-250 1450 25 20 52 2.62 5.5 1.4
80-50-200 2900 50 50 63 10.8 15 2.5
100-65-250 1450 50 20 63 4.3 7.5 2.5
100-65-200 2900 100 50 72 18.9 30 3.9
125-100-250 1450 100 20 72 7.56 11 2.3
125-100-315 2900 200 125 70 97.2 160 5.2
150-125-400 1450 200 50 70 38.9 55 3.5
200-150-400 1450 400 50 78 69.8 90 3.5
Only part of the product model demonstration
If the actual requirements of performance parameters and performance table does not match, can be based on user requirements for design and manufacture.

Sproull® ICJ Installation Drawing(Demonstration)

ICJ08
Type Installation Dimensions(mm)
a A L1 L2 L3 L4 B1 B2 4-Φd h H H1
ICJ200-150-400 160 110 2260 1800 1200 300 670 730 4-Φ26 315 465 915